FactoryTalk Historian SE

historian-se

Overview

The FactoryTalk® Historian Site Edition (SE) application provides you with the data capture, management, and analytical capabilities to help generate improved decision-making. ​Plant supervisors can view individual historical data for machines, process equipment, or production lines on demand. Production supervisors can analyze batch operations for an individual site against ente​rprise-wide corporate production parameters. Enterprise managers can compare KPIs among locations. This application helps locate and correct sources of inefficiencies quickly. This helps you manage manufacturing consistency, energy use, first-pass quality, and other factors that can improve the bottom line.

FactoryTalk Historian SE Product Profile

FactoryTalk Historian SE Product Profile

Secure, scalable, accessible: Use FactoryTalk Historian to drive data management for a better bottom line.

Read more


Info Access Drives Savings

Hillshire Brands improves yield by over 100,000 pounds.

Watch now


Data Generates Asset Utilization & Efficiency

Data Generates Asset Utilization & Efficiency

Easy updates give public works department advantages of MI.

Read more


Features

  • Premier integration to FactoryTalk® and Integrated Architecture™ allows for better and faster data collection from machines and devices on the plant floor
  • Auto Discovery and Auto Configuration helps reduce deployment time and lowers total cost of ownership
  • Robust and reliable data collection application
  • Powerful archive technology to help provide long-term data storage and fast, efficient retrieval of data
  • Comprehensive support for redundancy and high availability to ensure minimal data loss and constant access to data
  • Powerful advanced Server option providing Data access through standard interfaces (OPC/OLEDB/JDBC and Webservices), Advanced Calculation Engine and Notification Server

Benefits


  • Improve processes through the ability to analyze complex process data more easily
  • Reduce variability by verifying production parameters versus targets/norms
  • Respond to information requests from customers or regulators more easily through the maintenance of an accessible online record
  • Decrease overhead costs by saving time in collecting data and preparing reports
  • Reduce deployment of new systems by using automatic discovery mechanisms to get new equipment data collection configured fast
  • Connect to all equipment and data sources in your plant with Integrated Architecture and significant 3rd-party connectivity capability with FactoryTalk Historian connectors for most equipment in a plant
  • Enable full use of the collected data by using the various capabilities to calculate and aggregate the data collected from the data sources
  • Use a single, rich thin-client platform for all information and reporting requirements such as Microsoft Excel reports, powerful trends, dashboards, and portal access

Latest Releases

FactoryTalk Historian SE v4.0


  • Maximum Tag Count/Server: 500,000
  • Maximum Events/Server: 100,000 events/sec
  • Maximum Tag Count/Interface: 50,000
  • Maximum Events/Interface: 25,000 events/sec

System Requirements

Server Requirements


Operating System Windows Server 2008

  • R2 Standard Edition with Service Pack 1 64-bit

Additional Requirements

  • SQL Server 2008 R2 Express or Standard 32-bit or 64-bit

Live Data Interface Machine Requirements

Operating System Windows 7

  • Professional with Service Pack 1 32-bit or 64-bit

Windows Server 2008

  • R2 Standard Edition with Service Pack 1 64-bit
  • Standard Edition with Service Pack 2 32-bit or 64-bit

User Guides

FactoryTalk Historian SE Installation And Configuration Guide

Installation And Configuration Guide

Detailed information on the proper installation of FactoryTalk Historian SE.

Read more


Literature Library

More Related Literature

A broad range of material also available in Literature Library.

Browse FactoryTalk Historian SE Literature


Ordering Information

Ordering Information


FactoryTalk Historian SE Servers

Catalog Number Description
9518-HSE250 FT Historian Site Edition – 250 tags
D/C – E2
9518-HSE500 FT Historian Site Edition – 500 tags
D/C – E2
9518-HSE1K FT Historian Site Edition – 1,000 tags
D/C – E2
9518-HSE2K5 FT Historian Site Edition – 2,500 tags
D/C – E2
9518-HSE5K FT Historian Site Edition – 5,000 tags
D/C – E2
9518-HSE10K FT Historian Site Edition – 10,000 tags
D/C – E2
9518-HSE20K FT Historian Site Edition – 20,000 tags
D/C – E2
9518-HSE50K FT Historian Site Edition – 50,000 tags
D/C – E2
9518-HSE100K FT Historian Site Edition – 100,000 tags
D/C – E2

Note: Up to 1,000 data points or 20% of the total data points (whichever is higher) can be assigned to third-party devices.

FactoryTalk® Historian SE Servers — Advanced Server Option

FactoryTalk® Historian SE Advanced Server License adds the following capability: Data Access (OPC DA and HDA servers, OLE DB Provider, JDBC data provider and web services), Advanced Computation Engine (ACE), and Notifications for using Microsoft® Lync Unified Communication Server. The Advance Server Option also included data access interfaces for OLEDB, JDBC and Web Services for accessing the Historian data. New with this release is a separate catalog item for the OLEDB and OPC DA/HDA connectivity. The catalog information is listed in the table below.

Catalog Number Description
9518-HSEADV FT Historian SE – Advanced Server
D/C – E2
9518-HSEOPC FT Historian SE – OPC DA/HDA Connectivity
D/C – E2
9518-HSEOLEDB FT Historian SE – OLEDB Connectivity
D/C – E2

The Data Access components (OLEDB, JDBC, Web services, etc), require client licensing to consume data from the Historian database. The licensing model is similar to SQL Server licensing from Microsoft where there are two options: CAL – named user based and CAL – unlimited users. With the purchase of Advanced Server Option (9518-HSEADV) or OLEDB Connectivity (9518-HSEOLEDB) you will get the following client licensing:

  • 5 named users CAL license OR
  • Unlimited users CAL license (ONLY for FT Historian SE – 250 tags or 500 tags)

The following catalog items can be purchased for additional data access client licensing.

Catalog Number Description
9518-HCALENE Historian Client Access License – 1 Named User
D/C – E2
9518-HCAL1KENF Historian Client Access License – Unlimited Users for 1,000 Tags
D/C – E2
9518-HCAL2K5ENF Historian Client Access License – Unlimited Users for 2,500 Tags
D/C – E2
9518-HCAL5KENF Historian Client Access License – Unlimited Users for 5,000 Tags
D/C – E2
9518-HCAL10KENF Historian Client Access License – Unlimited Users for 10,000 Tags
D/C – E2
9518-HCAL20KENF Historian Client Access License – Unlimited Users for 20,000 Tags
D/C – E2
9518-HCAL50KENF Historian Client Access License – Unlimited Users for 50,000 Tags
D/C – E2
9518-HCAL100KENF Historian Client Access License – Unlimited Users for 100,000 Tags
D/C – E2

FactoryTalk Historian Clients

The FactoryTalk Historian clients are only available in named user mode. The concurrent licenses are no longer available except for the existing customers who had purchased the concurrent licenses with their system.

Catalog Number Description
9518-HPBENE FT Historian ProcessBook – Named User
D/C – E2
9518-HDLENE FT Historian DataLink – Named User
D/C – E2
9518-HAVENE FT Historian ActiveView – Named User
D/C – E2
9518-HBAVENE FT Historian BatchView Add-In – Named User
D/C – E2
9518-HSAENE FactoryTalk Historian SQC ProcessBook Add-in – Named User
D/C – E2

Create your own user feedback survey })(jQuery);